Specifications

 

Designed to Answer Your Needs

Ease of Operation
Compact Design
The J Series' advanced design and superior
engineering minimized both space and weight. Whether it's your backyard or in your basement, it will fit neatly in most any place you wish to put it.

High Output
Thanks to the engine's vertical design, this direct coupled 2-pole series is capable of producing high output.

Front Panel Control
Key switch, voltage meter, circuit breaker, and warning lamps are all conveniently and gathered on a drip proof control panel.

Large Capacity Fuel Tank
The larger capacity fuel tank enables longer periods of continuous operation on a single tank of fuel.

(hr)
Model
Continuous Operating Hours
at full load
at 3/4 load
at 1/2 load
50Hz
J106
16
19
23
J108
11.5
13.5
16.5
J112
17
20
26.5
J116
13
16.5
20.5
J310
11.5
13.5
16.5
J315
17
20
26.5
J320
13
16.5
20.5
60Hz
J107
13
15.5
19
J110
8.5
10.5
12.5
J114
13.5
16
20
J119
10.5
13
16
J313
16
10.5
12.5
J318
13.5
16
20
J324
10.5
13
16

Enhanced Transportability
A 1-point lifting eye and special forklift openings helped enhance the series transportability.


Easy Maintenance
Effortless Maintenance
All gauges and filters (except for Z482 and D722's oil filter) are conveniently situated to simplify daily maintenance.

Double Element Air Filter
A double element air filter is used in the J Series to withstand heavy-duty use, and to protect the generator from sand-caused damages.

Dependable Power
Transistor Automatic Voltage Regulator (AVR)
The J-Series uses a transistor AVR to ensure a stable flow of current for most any kind of jobs you can think of.

A Skewed Rotor & Damper Winding
The waveform distortion is kept to a minimum by the skewed rotor, while the damper winding protects the generator during short circuits, regulates voltage fluctuations during condensive loads, and withstands load fluctuations during condensive and non-linear loads.

Increased Safety
Emergency Unit
Automatically shut the engine down in case of abnormalities in oil pressure, water temperature, and when the fanbelt breaks*.
*Fanbelt accident prevention is only applicable to generators using D1005 and V1305 engines.

Electric Shock and Entangling Preventions
Protective covers are attached on all output terminals to prevent electric shocks. The number of safety covers has also been increased to prevent entangling accidents.

Access Terminals for Easy Wiring with AMF Panel or ATS
New access terminals are provided for easy wiring with the automatic start/stop system. These terminals are also for the AMF panel and the Automatic Transfer Switch, which are both options provided separately by the user.

 