KUBOTA GL SERIES DIESEL ENGINE GENERATORS
Specifications - 50 Hz & 60 Hz
Model

Model

Unit
For 50 Hz Area
For 60 Hz Area
GL6000
GL9000
GL7000
GL11000
Generator

Design

 
Rotating field single-phase AC generator

Standby Output

kW
6
8.8
7
11

Prime Output

kW
5.5
8
6.5
10

Voltage

V
220
110 / 220

Phase X Wire

 
1 X 2
1 X 4
1 X 3

No. of Poles

 
2

Insulation

 
Stator: B/Rotor: F

Voltage Compensation

 
AVR

Type of Coupling

 
Direct coupling
Diesel Engine

Model

 
Z482
D722
Z482
D722

Type

 
Vertical, 4-cycle liquid-cooled diesel engine

Starting System

 
Electric - 12 volt DC

Displacement

LTR. (cu.in.)
0.479 (29.2)
0.719 (43.9)
0.479 (29.2)
0.719 (43.9)

No. of Cylinders

 
2
3
2
3

Bore X Stroke

mm (in.)
67 X 68 (2.6 X 2.7)

Engine Speed

rpm
3000
3600

Cont. Rated Output

kW (HP)
6.9 (9.9)
10.3 (13.8)
8.1 (10.9)
12.2 (16.3)

Lubricating Oil

 
API Service Class CD or higher

Lubricating Oil Capacity

LTR. (U.S.gal.)
2.2 (0.58)
3.4 (0.90)
2.2 (0.58)
3.4 (0.90)

Coolant Capacity

LTR. (U.S.gal.)
3.7 (0.98)
4.1 (1.1)
3.7 (0.98)
4.1 (1.1)
Set

Fuel

 
Diesel fuel No. 2 (ASTM D975)

Fuel Tank Capacity

LTR. (U.S.gal.)
28 (7.4)

Fuel Consumption

at Full Load
LTR. (U.S.gal.)/h
2.4 (0.63)
3.3 (0.87)
2.7 (0.71)
4.1 (1.08)
at 3/4 Load
LTR. (U.S.gal.)/h
2.0 (0.53)
3.0 (0.79)
2.1 (0.55)
3.1 (0.82)
at 1/2 Load
LTR. (U.S.gal.)/h
1.6 (0.42)
2.3 (0.61)
1.5 (0.40)
2.2 (0.58)
at 1/4 Load
LTR. (U.S.gal.)/h
1.3 (0.34)
1.7 (0.45)
1.1 (0.29)
1.5 (0.40)

Continuous Operating Hours at Full Load

hours
12
8.5
10
7

Battery

V-Ah/5hr
38B20R (12V X 28Ah)
55B24R (12V X 36Ah)
38B20R (12V C 28Ah)
55B24R (12V X 36Ah)

Type of Stop Solenoid

 
Energized-to-Stop

Sound Level      Full Load at 7m (23ft.)

dB (A)
65
67
66
68

Dimensions

L
mm (in.)
1066 (42.0)
1281 (50.4)
1066 (42.0)
1281 (50.4)
W
mm (in.)
618 (24.3)
618 (24.3)
618 (24.3)
618 (24.3)
H
mm (in.)
698 (27.5)
698 (27.5)
698 (27.5)
698 (27.5)

Approx. Dry Net Weight

kg (lbs.)
235 (518)
295 (650)
235 (518)
295 (650)

Emergency Stop System

 
In case of abnormal: oil pressure, water temperature, or when the access terminal cover is opened.
AMPS

Single Phase 110V

A
-
-
59.1
90.9

Single Phase 220V

A
25
36.4
29.5
45.5
No. of Receptacles

5-15R

 
0
0
2
2

6-15R

 
2
2
0
0
Terminals

Output Connection

 
Available
Options

Two wheel kit

 
Available

Romote control kit

 
Available

 

© Copyright 2005 Central Power Equipment. All Rights Reserved. A Web Experience by Genesis Solution Enterprise